NEK606 Instrumentation Cables S2 or S2/S6 RFOU(c) 250V:
Applications
S2 or S2/S6 RFOU(i) 250V Marine Cable s are flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication,control and alarm systems.
Standards
| IEC 60092-376 | IEC 60092-351 | 
| IEC 60092-359 | IEC 60332-1 | 
| IEC 60332-3-22 | IEC 60754-1,2 | 
| IEC 61034-1,2 | NEK 606:2004 | 
-250V-1-1.jpg) 
Construction
- Conductors : Circular tinned annealed stranded copper wire to IEC 60228 class 2.
- Insulation : Halogen free EPR compound.
- Twinning : Colour coded cores twisted together.
- Collective Shielding : Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
- Bedding : Halogen free compound.
- Armour : Tinned copper wire braid.
- Outer Sheath : Halogen free thermosetting compound, SHF2 (for TYPE S2). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S2/S6), coloured grey (blue for intrinsically safe).
	Technical data
	
		
			
				
					Nominal Cross Section
  Area
				 
				
					mm²
				 
				
					0.75
				 
				
					1
				 
				
					1.5
				 
				
					2.5
				 
			 
			
				
					Nominal Conductor Diameter
				 
				
					mm
				 
				
					1.1
				 
				
					1.3
				 
				
					1.6
				 
				
					2
				 
			 
			
				
					Maximum Resistant@20℃
				 
				
					Ω/km
				 
				
					26.3
				 
				
					19.3
				 
				
					12.9
				 
				
					8.02
				 
			 
			
				
					Mutual Capacitance
				 
				
					nF/km
				 
				
					80
				 
				
					90
				 
				
					100
				 
				
					110
				 
			 
			
				
					Nominal Inductance@1KHz
				 
				
					MH/km
				 
				
					0.682
				 
				
					0.645
				 
				
					0.632
				 
				
					0.593
				 
			 
			
				
					Maximum L/R@1KHz
				 
				
					μH/Ω
				 
				
					20
				 
				
					25
				 
				
					35
				 
				
					50
				 
			 
			
				
					Operating Voltage
				 
				
					V
				 
				
					250
				 
				
					250
				 
				
					250
				 
				
					250
				 
			 
		
	
| Nominal Cross Section Area | mm² | 0.75 | 1 | 1.5 | 2.5 | 
| Nominal Conductor Diameter | mm | 1.1 | 1.3 | 1.6 | 2 | 
| Maximum Resistant@20℃ | Ω/km | 26.3 | 19.3 | 12.9 | 8.02 | 
| Mutual Capacitance | nF/km | 80 | 90 | 100 | 110 | 
| Nominal Inductance@1KHz | MH/km | 0.682 | 0.645 | 0.632 | 0.593 | 
| Maximum L/R@1KHz | μH/Ω | 20 | 25 | 35 | 50 | 
| Operating Voltage | V | 250 | 250 | 250 | 250 | 
Mechanical and Thermal Properties
- Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
- Temperature Range : -20℃ ~ +90℃.

-250V-1.jpg) 
                                