Marine Cable-RG58 Armoured Coaxial Cable:
Applications
RG58 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
| IEC 60092-350 | IEC 60332-3-22 | 
| IEC 60754-1,2 | IEC 61034-1,2 | 
| NEK 606:2004 | 
 
Construction
- Conductors: 21AWG tinned copper.
- Insulation : PE.
- Shielding : Tinned copper braid.
- Bedding : Low smoke and halogen-free polyolefin, coloured black.
- Armour : Copper wire braid.
- Outer Sheath : Low smoke and halogen-free polyolefin.
Technical Data
| AWG | 21 | |
| Conductor Construction No./Diameter of Wires | -/mm | 19/0.18 | 
| Nominal Conductor Diameter | mm | 0.89 | 
| Impedance | Ω | 50+/-3 | 
| Nominal Attenuation@100MHz | dB/100m | 15.7 | 
| Nominal Attenuation@200MHz | dB/100m | 22.3 | 
| Nominal Attenuation@400MHz | dB/100m | 32.8 | 
| Nominal Attenuation@700MHz | dB/100m | 46.6 | 
| Nominal Attenuation@900MHz | dB/100m | 54.1 | 
| Nominal Attenuation@1000MHz | dB/100m | 56.1 | 
| Capacitance | pF/m | 101 | 
| Velocity of Propagation | % | 66 | 
| Conductor DCR | Ω/km | 35.4 | 
| Inductance | μH/m | 0.246 | 
| Time Delay | ns/m | 5 | 
Mechanical and Thermal Properties
- Bending Radius : 15×OD.
- Temperature Range : -30℃ ~ +75℃.
Dimensions and Weight
| Nominal Inner Conductor Diameter mm | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km | 
| 0.89 | 1.0 | 1.14 | 8.6 | 149 | 

 
                                