Applications
These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.
Standards
| IEC 60092-376 | IEC 60092-351 |
| IEC 60092-359 | IEC 60332-1 |
| IEC 60332-3-22 | IEC 60754-1,2 |
| IEC 61034-1,2 | NEK 606:2004 |
Construction
- Conductors : Circular tinned annealed stranded copper wire to IEC 60228 class 2.
- Insulation : Halogen free EPR compound.
- Twinning : Colour coded cores twisted together.
- Collective Shielding : Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
- Outer Sheath : Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
Technical Data
Nominal Cross Section Area mm² 0.75 1 1.5 Nominal Conductor Diameter mm 1.1 1.3 1.6 Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 Mutual Capacitance nF/km 80 90 100 Nominal Inductance@1KHz MH/km 0.682 0.645 0.632 Maximum L/R@1KHz μH/Ω 20 25 35 Operating Voltage V 250 250 250
| Nominal Cross Section Area | mm² | 0.75 | 1 | 1.5 |
| Nominal Conductor Diameter | mm | 1.1 | 1.3 | 1.6 |
| Maximum Resistant@20℃ | Ω/km | 26.3 | 19.3 | 12.9 |
| Mutual Capacitance | nF/km | 80 | 90 | 100 |
| Nominal Inductance@1KHz | MH/km | 0.682 | 0.645 | 0.632 |
| Maximum L/R@1KHz | μH/Ω | 20 | 25 | 35 |
| Operating Voltage | V | 250 | 250 | 250 |
Mechanical and Thermal Properties
- Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
- Temperature Range : -20℃ ~ +90℃.