NEK606 Telecommunication S10 IYOI(c) 60V Marine Cable:
Applications
These cables are flame retardant, low smoke and halogen free, used for indoor telecommunication.
Standards
| IEC 60092-359 | IEC 60332-1 | 
| IEC 60332-3-22 | IEC 60754-1,2 | 
| IEC 61034-1,2 | NEK 606:2004 | 
-60V-Marine-Cable1.jpg) 
Construction :
- Conductors : Solid tinned copper, 0.5mm.
- Insulation : Halogen-free thermoplastic compound PE.
- Twinning : Colour coded cores twisted together. Pairs are cross-stranded to finished cable or 10 pair units. The units are stranded to 20 - 30 - 50 pair cables. 2 pair is stranded as a star quad.
- Wrapping : Polyester tape.
- Collective Shielding : The cable core is screened by copper backed polyester tape in contact with a 0.5mm solid tinned drain wire.
- Bedding : Halogen-free thermoplastic compound, type SHF1, coloured grey.
- Armour : Copper wire braid.
- Outer Sheath : Halogen-free thermoplastic compound, type SHF1, coloured grey.
Technical Data
| Nominal Conductor Diameter | mm | 0.5 | 
| Maximum Resistant@20℃ | Ω/km | 95 | 
| Nominal Inductance@1KHz | MH/km | 0.61 | 
| Mutual Capacitance 1-pair cable | nF/km | 90 | 
| Mutual Capacitance 2-pair cable | nF/km | 80 | 
| Mutual Capacitance 4-pair and above cable | nF/km | 70 | 
| Operating Voltage | V | 60 | 
Mechanical and Thermal Properties
- Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
- Temperature Range : -10℃ ~ +60℃.

-60V-Marine-Cable.jpg) 
                                