NEK606 Instrumentation Cables S12 RU(c) 250V Marine Cable:
Applications
These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.
Standards
| 
				 IEC 60092-376  | 
			
				 IEC 60092-351  | 
		
| 
				 IEC 60092-359  | 
			
				 IEC 60332-1  | 
		
| 
				 IEC 60332-3-22  | 
			
				 IEC 60754-1,2  | 
		
| 
				 IEC 61034-1,2  | 
			
				 NEK 606:2004  | 
		
Construction
- Conductors : Circular tinned annealed stranded copper wire to IEC 60228 class 2.
 - Insulation : Halogen free EPR compound.
 - Twinning : Colour coded cores twisted together.
 - Collective Shielding : Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
 - Outer Sheath : Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).
 
	
		Technical Data
	
	
		
			
				
					Nominal Cross Section
  Area
				 
				
					mm²
				 
				
					0.75
				 
				
					1
				 
				
					1.5
				 
			 
			
				
					Nominal Conductor Diameter
				 
				
					mm
				 
				
					1.1
				 
				
					1.3
				 
				
					1.6
				 
			 
			
				
					Maximum Resistant@20℃
				 
				
					Ω/km
				 
				
					26.3
				 
				
					19.3
				 
				
					12.9
				 
			 
			
				
					Mutual Capacitance
				 
				
					nF/km
				 
				
					80
				 
				
					90
				 
				
					100
				 
			 
			
				
					Nominal Inductance@1KHz
				 
				
					MH/km
				 
				
					0.682
				 
				
					0.645
				 
				
					0.632
				 
			 
			
				
					Maximum L/R@1KHz
				 
				
					μH/Ω
				 
				
					20
				 
				
					25
				 
				
					35
				 
			 
			
				
					Operating Voltage
				 
				
					V
				 
				
					250
				 
				
					250
				 
				
					250
				 
			 
		
	
| Nominal Cross Section Area | mm² | 0.75 | 1 | 1.5 | 
| Nominal Conductor Diameter | mm | 1.1 | 1.3 | 1.6 | 
| Maximum Resistant@20℃ | Ω/km | 26.3 | 19.3 | 12.9 | 
| Mutual Capacitance | nF/km | 80 | 90 | 100 | 
| Nominal Inductance@1KHz | MH/km | 0.682 | 0.645 | 0.632 | 
| Maximum L/R@1KHz | μH/Ω | 20 | 25 | 35 | 
| Operating Voltage | V | 250 | 250 | 250 | 
Mechanical and Thermal Properties
- Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
 - Temperature Range : -20℃ ~ +90℃.
 

                                -250V-Marine-Cable-1.jpg)