JIS C 3410 250V MPY-S FA-MPY-S Control and Signal Cable:
CABLE DESIGNATION
250V MPY-S, FA-MPY-S
250V MPYC-S, FA-MPYC-S
250V MPYCY-S, FA-MPYCY-S
APPLICATION STANDARD
- Design guide : JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35℃ ) (Cold Type)
- Max. conductor temperature : 85℃
TECHNICAL DATA
1. CABLE TYPE:250V (FA-)MPY-S, 250V (FA-)MPYC-S, 250V (FA-)MPYCY-S
No. of Pair, Triad or Quad: 2, 4, 5, 7, 9, 12, 16, 19, 23, 27, 33, 37, 44, 77.
Nominal Area(mm2):1.0
| Classification | Code | Construction Detail | 
| 
					Conductor | 
				M | Stranded tinned annealed copper wires as per JIS C 3410. | 
| Insulation | P | EPR as per JIS C 3410. | 
| Individual shield | -S | Tinned copper wire braid | 
| Cabling | 
					Insulated conductors shall be
 cabled. Flame retardant & non-hygroscopic fillers may be used. Suitable tape(s) may be applied on the cabled core.  | 
			|
| Sheath | Y | PVC as per JIS C 3410. | 
| Armor | C | 
					Braid of galvanized steel
 wires. Coverage density is minimum 90%.  | 
			
| Paint | 
					The white paint shall be painted
 uniformly on the steel wire braid Protective covering Type, paint is dispensable.  | 
			|
| Protective Covering | Y | 
					PVC as per JIS C 3410. Outer sheath color : Black  | 
			
| Core identification | Black No. on white insulation | |
| 
					Note Fire resistant type (“FRA-”) & Cold type cable (“(C)”) can be supplied.  | 
			||

                                
                                